Difference between revisions of "Publications:A wearable gait analysis system using inertial sensors Part I : Evaluation of measures of gait symmetry and normality against 3D kinematic data"

From ISLAB/CAISR
Jump to navigationJump to search
(Created page with "<div style='display: none'> == Do not edit this section == </div> {{PublicationSetupTemplate|Author=Anita Sant'Anna, Nicholas Wickström, Roland Zügner, Roy Tranberg |PID=516...")
 
 
Line 4: Line 4:
 
{{PublicationSetupTemplate|Author=Anita Sant'Anna, Nicholas Wickström, Roland Zügner, Roy Tranberg
 
{{PublicationSetupTemplate|Author=Anita Sant'Anna, Nicholas Wickström, Roland Zügner, Roy Tranberg
 
|PID=516201
 
|PID=516201
|Name=Sant'Anna, Anita [anisan] (Högskolan i Halmstad [2804], Sektionen för Informationsvetenskap, Data– och Elektroteknik (IDE) [3905], Halmstad Embedded and Intelligent Systems Research (EIS) [3938], Laboratoriet för intelligenta system [6703]);Wickström, Nicholas [nicholas] (Högskolan i Halmstad [2804], Sektionen för Informationsvetenskap, Data– och Elektroteknik (IDE) [3905], Halmstad Embedded and Intelligent Systems Research (EIS) [3938], Laboratoriet för intelligenta system [6703]);Zügner, Roland (Department of Orthopedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden);Tranberg, Roy (Department of Orthopedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden)
+
|Name=Sant'Anna, Anita (anisan) (0000-0002-3495-2961) (Högskolan i Halmstad (2804), Sektionen för Informationsvetenskap, Data– och Elektroteknik (IDE) (3905), Halmstad Embedded and Intelligent Systems Research (EIS) (3938), Laboratoriet för intelligenta system (6703));Wickström, Nicholas (nicholas) (0000-0002-4143-2948) (Högskolan i Halmstad (2804), Sektionen för Informationsvetenskap, Data– och Elektroteknik (IDE) (3905), Halmstad Embedded and Intelligent Systems Research (EIS) (3938), Laboratoriet för intelligenta system (6703));Zügner, Roland (Department of Orthopedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden);Tranberg, Roy (Department of Orthopedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden)
 
|Title=A wearable gait analysis system using inertial sensors Part I : Evaluation of measures of gait symmetry and normality against 3D kinematic data
 
|Title=A wearable gait analysis system using inertial sensors Part I : Evaluation of measures of gait symmetry and normality against 3D kinematic data
 
|PublicationType=Conference Paper
 
|PublicationType=Conference Paper
Line 21: Line 21:
 
|Edition=
 
|Edition=
 
|Pages=
 
|Pages=
|City=[S. l.]
+
|City=(S. l.)
 
|Publisher=SciTePress
 
|Publisher=SciTePress
 
|Series=
 
|Series=
Line 55: Line 55:
 
|CreatedDate=2012-04-17
 
|CreatedDate=2012-04-17
 
|PublicationDate=2012-04-18
 
|PublicationDate=2012-04-18
|LastUpdated=2014-09-05
+
|LastUpdated=2016-03-09
 
|diva=http://hh.diva-portal.org/smash/record.jsf?searchId=1&pid=diva2:516201}}
 
|diva=http://hh.diva-portal.org/smash/record.jsf?searchId=1&pid=diva2:516201}}
 
<div style='display: none'>
 
<div style='display: none'>

Latest revision as of 22:42, 30 September 2016

Do not edit this section

Property "Publisher" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user.

Keep all hand-made modifications below

Title A wearable gait analysis system using inertial sensors Part I : Evaluation of measures of gait symmetry and normality against 3D kinematic data
Author
Year 2012
PublicationType Conference Paper
Journal
HostPublication BIOSIGNALS 2012 - Proceedings of the International Conference on Bio-Inspired Systems and Signal Processing
Conference International Conference on Bio-inspired Systems and Signal Processing, BIOSIGNALS 2012, Vilamoura, Algarve, 1-4 February, 2012
DOI
Diva url http://hh.diva-portal.org/smash/record.jsf?searchId=1&pid=diva2:516201
Abstract

Gait analysis (GA) is an important tool in the assessment of several physical and cognitive conditions. The lack of simple and economically viable quantitative GA systems has hindered the routine clinical use of GA in many areas. As a result, patients may be receiving sub-optimal treatment. The present study introduces and evaluates measures of gait symmetry and gait normality calculated from inertial sensor data. These indices support the creation of mobile, cheap and easy to use quantitative GA systems. The proposed method was compared to measures of symmetry and normality derived from 3D kinematic data. Results show that the proposed method is well correlated to the kinematic analysis in both symmetry (r=0.84, p<0.0001) and normality (r=0.81, p<0.0001). In addition, the proposed indices can be used to classify normal from abnormal gait.