Publications:Assessment of Gait Symmetry and Gait Normality Using Inertial Sensors : In-Lab and In-Situ Evaluation

From ISLAB/CAISR
Revision as of 12:49, 13 March 2014 by SlawekBot (talk | contribs) (Created page with "<div style='display: none'> == Do not edit this section == </div> {{PublicationSetupTemplate|Author=Anita Sant'Anna, Nicholas Wickström, Helene Eklund, Roland Zügner, Roy Tr...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Do not edit this section

Property "Publisher" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user. Property "Author" has a restricted application area and cannot be used as annotation property by a user.

Keep all hand-made modifications below

Title Assessment of Gait Symmetry and Gait Normality Using Inertial Sensors : In-Lab and In-Situ Evaluation
Author
Year 2013
PublicationType Book Chapter
Journal
HostPublication Biomedical Engineering Systems and Technologies : 5th International Joint Conference, BIOSTEC 2012, Vilamoura, Portugal, February 1-4, 2012, Revised Selected Papers
Conference
DOI http://dx.doi.org/10.1007/978-3-642-38256-7_16
Diva url http://hh.diva-portal.org/smash/record.jsf?searchId=1&pid=diva2:651767
Abstract

Quantitative gait analysis is a powerful tool for the assessment of a number of physical and cognitive conditions. Unfortunately, the costs involved in providing in-lab 3D kinematic analysis to all patients is prohibitive. Inertial sensors such as accelerometers and gyroscopes may complement in-lab analysis by providing cheaper gait analysis systems that can be deployed anywhere. The present study investigates the use of inertial sensors to quantify gait symmetry and gait normality. The system was evaluated in-lab, against 3D kinematic measurements; and also in-situ, against clinical assessments of hip-replacement patients. Results show that the system not only correlates well with kinematic measurements but it also corroborates various quantitative and qualitative measures of recovery and health status of hip-replacement patients